Technical Data > Resistance Ratios and Beta Values Table
Print Page | Download a PDF
Resistance Ratios and Beta Values Table
This table lists R0/R70, R0/R50, and R25/R125 Resistance Ratios and Beta Values for the temperature ranges 0 °C to 50 °C, 25 °C to 85 °C, and 25 °C to 125 °C for Cornerstone Sensors’ standard R/T Curves. For additional information about these characteristics, click on Resistance/Temperature Ratio or Beta Value here.


R/T Curve B D E F G R V W
Typical Resistance Range
(ohms at 25 °C)
0.2k to 2k 1k to 100k 20k to 50k 5k to 30k 20k to 100k 20k to 100k 50 to 500 0.2k to 2k
Nominal Resistance
(ohms at 25 °C)
1,000 10,000 30,000 10,000 100,000 100,000 200 1,000
R0/R70 Resistance Ratio 12.96 18.65 17.73 14.82 20.35 22.64 10.35 11.65
R0/R50 Resistance Ratio 6.89 9.06 8.66 7.58 9.58 10.45 5.81 6.35
R25/R125 Resistance Ratio 19.38 29.25 29.10 23.47 34.82 37.85 n/a 17.27
Beta Value, 0 °C to 50 °C 3407 3891 3811 3575 3989 4142 3107 3262
Beta Value, 25 °C to 85 °C 3486 3978 3943 3694 4144 4261 3185 3348
Beta Value, 25 °C to 125 °C 3519 4007 4001 3746 4214 4313 n/a 3382